SiENBE04-808_A Functions
List of Functions 2
1. Functions
1.1 Cooling Only
Category Functions
FTXS20/25/35/42G2V1B
RKS20/25/35/42G2V1B
RKS20/25/35G2V1B9
FTXS50G2V1B
RKS50G2V1B
Category Functions
FTXS20/25/35/42G2V1B
RKS20/25/35/42G2V1B
RKS20/25/35G2V1B9
FTXS50G2V1B
RKS50G2V1B
Basic
Function
Inverter
(with Inverter Power Control)
{{
Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°CDB)
–10
~46
H
–10
~46H
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°CWB) — —
Air-Purifying Filter with
Photocatalytic Deodorizing Function
——
PAM Control {{
Standby Electricity Saving { —
Titanium Apatite Photocatalytic
Air-Purifying Filter
{{
Compressor Oval Scroll Compressor — —
Swing Compressor {{ Air Filter (Prefilter) {{
Rotary Compressor — — Wipe-Clean Flat Panel {{
Reluctance DC Motor {{ Washable Grille — —
Comfortable
Airflow
Power-Airflow Flap — — MOLD PROOF Operation — —
Power-Airflow Dual Flaps {{ Good-Sleep Cooling Operation — —
Power-Airflow Diffuser — — Timer WEEKLY TIMER Operation {{
Wide-Angle Louvers {{ 24-Hour ON/OFF TIMER {{
Vertical Auto-Swing (Up and Down) {{ NIGHT SET Mode {{
Horizontal Auto-Swing
(Right and Left)
{{
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) {{
3-D Airflow {{
Self-Diagnosis (Digital, LED)
Display
{{
COMFORT AIRFLOW Operation {{ Wiring Error Check — —
Comfort
Control
Auto Fan Speed {{
Anti-Corrosion Treatment of
Outdoor Heat Exchanger
{{
Indoor Unit Quiet Operation {{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{
NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit {{
OUTDOOR UNIT QUIET Operation
(Manual)
{{ Flexible Voltage Correspondence — —
2-Area INTELLIGENT EYE Operation {{ High Ceiling Application — —
INTELLIGENT EYE Operation — — Chargeless 10 m 10 m
Quick Warming Function
(Preheating Operation)
— — Either Side Drain (Right or Left) {{
Hot-Start Function — — Power Selection — —
Automatic Defrosting — —
Remote
Control
5-Rooms Centralized Controller
(Option)
{{
Operation Automatic Operation — — Remote Control Adapter
(Normal Open Pulse Contact)
(Option)
{{
Program Dry Operation {{
Fan Only {{
Remote Control Adapter
(Normal Open Contact) (Option)
{{
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
DIII-NET Compatible (Adapter)
(Option)
{{
Inverter POWERFUL Operation {{Remote
Control
Wireless {{
Priority-Room Setting — — Wired (Option) {{
COOL / HEAT Mode Lock — —
HOME LEAVE Operation — —
ECONO Operation {{
Indoor Unit ON/OFF Button {{
Signal Receiving Sign {{
Temperature Display — —
Note: { : Holding Functions
— : No Functions
H
: Lower limit can be extended to –15°C by cutting
jumper (20-42 class) or turning switch (50 class).