Indoor Unit SiENBE04-808_A
179 Removal Procedure
2. Remove the swing motor
for horizontal blade. Caution
When reassembling, do not
confuse the installing order
of the 2 motors and the
colors of the connectors.
If you set the connectors or
motors opposite, the
horizontal blades do not
move smoothly or the noise
may be heard.
(1) Set the motor for the upper
blade first.
(connector: white)
(2) Then, set the motor for the
lower blade.
(connector: red)
(3) Fix the both motors with a
screw.
1
Remove the screw and
remove the swing
motors for horizontal
blades.
2
Disconnect the
harnesses from the
motors.
Step Procedure Points
(R8131)
Connector for
lower blade (red)
Connector for
upper blade (white)
Screw
(R8132)
(R10335)
SiENBE04-808_A.pdf 191 21/02/2011 13:20:10