SiENBE04-808_A Specifications
Specifications 8
50 Hz, 220 - 230 - 240 V
Note: The data are based on the conditions shown in the table below.
Models
Indoor Units FTXS42G2V1B FTXS50G2V1B
Outdoor Units RKS42G2V1B RKS50G2V1B
Capacity
Rated (Min. ~ Max.)
kW 4.2 (1.7 ~ 5.0) 5.0 (1.7 ~ 5.3)
Btu/h 14,300 (5,800 ~ 17,100) 17,100 (5,800 ~ 18,100)
kcal/h 3,610 (1,460 ~ 4,300) 4,300 (1,460 ~ 4,560)
Moisture Removal L/h 2.3 2.8
Running Current (Rated) A 6.2 - 5.9 - 5.6 7.1 - 6.7 - 6.5
Power Consumption
Rated (Min. ~ Max.)
W 1,220 (440 ~ 2,230) 1,520 (440 ~ 1,810)
Power Factor % 89.4 - 89.9 - 90.8 97.3 - 98.6 - 97.4
COP (Rated) W/W 3.44 (3.86 ~ 2.24) 3.29 (3.86 ~ 2.93)
Piping
Connections
Liquid mm φ 6.4 φ 6.4
Gas mm φ 9.5 φ 12.7
Drain mm φ 18.0 φ 18.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 20 30
Max. Interunit Height Difference m 15 20
Chargeless m 10 10
Amount of Additional Charge of
Refrigerant
g/m 20 20
Indoor Units FTXS42G2V1B FTXS50G2V1B
Front Panel Color White White
Airflow Rate
m³/min
(cfm)
H 9.1 (321) 10.2 (360)
M 7.7 (273) 8.6 (305)
L 6.3 (221) 7.0 (246)
SL 5.4 (190) 6.0 (212)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 23 23
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.11 - 0.11 - 0.10 0.12 - 0.12 - 0.11
Power Consumption (Rated) W 24 - 24 - 24 26 - 26 - 26
Power Factor % 99.2 - 94.9 - 100.0 98.5 - 94.2 - 98.5
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 295 × 800 × 215 295 × 800 × 215
Packaged Dimensions (H × W × D) mm 274 × 870 × 366 274 × 870 × 366
Weight kg 10 10
Gross Weight kg 13 13
Operation
Sound
H / M / L / SL dBA 42 / 38 / 33 / 30 43 / 39 / 34 / 31
Sound Power dBA 58 59
Outdoor Units RKS42G2V1B RKS50G2V1B
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC36BXD 2YC36BXD
Motor Output W 1,100 1,100
Refrigerant
Oil
Type FVC50K FVC50K
Charge L 0.65 0.65
Refrigerant
Type R-410A R-410A
Charge kg 1.30 1.70
Airflow Rate
m³/min
(cfm)
HH 37.3 (1,317) 50.9 (1,797)
SL 30.6 (1,079) 48.9 (1,727)
Fan
Type Propeller Propeller
Motor Output W 50 53
Running Current (Rated) A 6.04 - 5.78 - 5.54 6.93 - 6.63 - 6.35
Power Consumption (Rated) W 1,196 - 1,196 - 1,196 1,494 - 1,494 - 1,494
Power Factor % 90.0 - 90.0 - 90.0 98.0 - 98.0 - 98.0
Starting Current A 6.2 7.1
Dimensions (H × W × D) mm 550 × 765 × 285 735 × 825 × 300
Packaged Dimensions (H × W × D) mm 612 × 906 × 364 797 × 960 × 390
Weight kg 39 47
Gross Weight kg 45 52
Operation
Sound
H / SL dBA 48 / 44 48 / 44
Sound Power H dBA 63 62
Drawing No. 3D059730 3D059731
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
5 m