EasyManua.ls Logo

Daikin FTXS20G2V1B - Page 314

Daikin FTXS20G2V1B
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiENBE04-808_A Wiring Diagrams
Appendix 302
RXS42G2V1B, ARXS42G2V1B
RKS50G2V1B
MRM10
BRN
M1F : FAN MOTOR
MRCW, MRM10,
MRM20, MR30 : MAGNETIC RELAY
N
: NEUTRAL
PCB1 : PRINTED CIRCUIT BOARD
Q1L : OVERLOAD PROTECTOR
R1T~R3T : THERMISTOR
SA1 : SURGE ARRESTER
Q31 : IGBT
HL1
YLW
YLW
V
HR2
(CONDENSER)
BLK
S20
2
BLU
BLK
FU2
3.15A
R2T
V3
S90
DB2
W
BLK
DB3
Q1L
6
L
M1F
E
FU1
BRN
M
R3T
Z1C
ORG
V1
FU3
RED
V
BLK
X11A
MRM20
HR1
1
Z2C
3
S80
1
N=3
S
N=3
RED
HN1
S70
BLK
RED
N=7
30A
Z4C
3~
IPM1
C95
L1R
BRN
M1C
V4
MR30
E2
C94
N
BLK
C74, C75, C94
C95 : CAPACITOR
DB1, DB2, DB3 : DIODE BRIDGE
FU1, FU2, FU3 : FUSE
IPM1 : INTELLIGENT POWER MODULE
L : LIVE
L1 : COIL
L1R : REACTOR
M1C : COMPRESSOR MOTOR
M
W
M
R1T
L1
1
indoor
RED
WHT
SA1
WHT
3
BLK
YLW
GRN/YLW
DB1
ORG
Z3C
V1, V3, V4 : VARISTOR
X1M
: TERMINAL STRIP
Y1E
: ELECTRONIC EXPANSION VALVE COIL
Y1R : REVERSING SOLENOID VALVE COIL
Z1C, Z2C, Z3C
Z4C : FERRITE CORE
: PROTECTIVE EARTH
S20, S40, S70
S80, S90
X11A : CONNECTOR
Y1R
C75
L
outdoor
(OUTDOOR)
PCB1
N
BLU
1
BLU
(DISCHARGE)
WHT
Q31
U
311
3.15A
2
N=3
X1M
2
W
6
FIELD WIRING
C74
1~
BLU
U
BLK
U
BLK
RED
S40
MRCW
GRN
BLU
Y1E
1
7
BLU
V
ORG
BLK : BLACK
BLU : BLUE
BRN : BROWN
GRN : GREEN
ORG : ORANGE
RED : RED
WHT : WHITE
YLW : YELLOW
~
~
+
_
~
~
+
_
~
~
+
_
+
_
+
_
+
_
+
_
+
_
POWER
SUPPLY
3D059601
outdoor
FIELD WIRING
indoor
S2
BLU
BRN
FU3
1
3.15A
1
WHT
TO INDOOR UNIT
BLU
8
POWER SUPPLY
YLW
BLK
BRN
BRN
FU1
MRM10
S10
1
3
BLU
5
BLU
V6
SHEET METAL
7
V3
YLW
RED
S40
AC1
BLK
Z3C
MRM10, MRM20
MRC/W : MAGNETIC RELAY
R1T~R3T : THERMISTOR
S2~S102 : CONNECTOR
LEDA : PILOT LAMP
GRN
BLU
6(P)
BRN
M
Z5C
PCB1
1
S102
WHT
1
Z4C
BLK
L
BLU
5
SW4
M1F
3
N
E1
2
6
2
1
E2
4
ORG
BLK
3
FU2
R2T
BLK
V2
BLU
M1C
PM1
YLW
V
WHT
V5
M1C : COMPRESSOR MOTOR
M1F : FAN MOTOR
L1R : REACTOR
Q1L : OVERLOAD PROTECTOR
PM1 : POWER MODULE
PCB1,2 : PRINTED CIRCUIT BOARD
STEEL METAL
WHT
S90
LED A
BLU
L
1
4
3
2
7(N)
GRN
U
Q1L
1
1
RED
1
HR2
M
3~
RED
V
S101
ORG
X11A
1
Z1C
WHT
L : LIVE
N : NEUTRAL
SW1 :
FORCED OPERATION ON/OFF SW (SW1)
SW4 : LOCAL SETTING SW (SW4)
9
N
Z1C~Z5C : FERRITE CORE
X1M, X2M : TERMINAL STRIP
Y1E :
ELECTRONIC EXPANSION VALVE COIL
V2, V3, V5, V6, V11 : VARISTOR
SA2 : SURGE ARRESTER
FU1, FU2, FU3 : FUSE
AC1, AC2
U, V, W, X11A, X12A
E1, E2
HR1, HR2 : CONNECTOR
R1T
U
YLW
V11
PCB2
5
BLU
MRC
L1R
GRN
HR1
S80
1
S52
W
RED
M
6
WHT
GRN
RED
3.15A
30A
BLK
MRM20
X1M
BLU
S51
W
WHT
RED
BLU
S20
W
X2M
5
X12A
1
BLK
SW1
ORG
AC2
Y1E
S70
R3T
SA2
5
Z2C
RED
: TERMINAL STRIP FIXED PLATE
t° t° t°
+++
(OUTDOOR) (DISCHARGE)
(CONDENSER)
3D056145A
SiENBE04-808_A.pdf 314 21/02/2011 13:20:28

Table of Contents

Other manuals for Daikin FTXS20G2V1B

Related product manuals