SiENBE04-808_A Main Functions
Function and Control 40
2. Motions (for example: in cooling)
When the microcomputer does not have a signal from the sensor in 20 minutes, it judges
that nobody is in the room and operates the unit in temperature shifted from the target
temperature. (Cooling / Dry : 2°C higher, Heating : 2°C lower, Auto : according to the
operation mode at that time.)
H1 In case of FAN mode, the fan speed reduces by 60 rpm.
3. Airflow direction in 2-area INTELLIGENT EYE operation
Detection method: The opposite area of detected area is set as the target direction.
1. Detection signal ON in both area A and B: Shift the airflow direction to area B (left side)
2. Detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Detection signal OFF in both area A and B: No change
* When the detection signal is OFF for 20 minutes in both area A and B, the unit starts energy
saving operation.
Others For dry operation, you cannot set the temperature with remote control, but internally the
target temperature is shifted by 2°C.
ON
OFF
RESET.
(From area A or B)
20 min. 20 min.
ON
OFF
ON
OFF
Operation
OFF
Fan speed (H1)
Set speed Set speed
Target temperature
(R12183)
Remote control
INTELLIGENT EYE
button
ON
OFF
INTELLIGENT EYE
lamp
within 20
minutes
Human detection
signal
Top view
Wall
Indoor unit
Area A
Area B
Left
Right
Human
(R3853)
SiENBE04-808_A.pdf 52 21/02/2011 13:19:56