SiENBE04-808_A Control Specification
Function and Control 52
RK(X)S20-35G2V1B9, ARXS20-35G3V1B
Limitation of current drooping and stop value according to the outdoor temperature
The current droops when outdoor temperature becomes higher than a certain level
(depending on the model).
20 class 25 class 35 class
Cooling Heating Cooling Heating Cooling Heating
(A) 9.25 9.25 9.25
(A) Normal mode 6.0 7.5 6.25 7.5 8.25
ECONO mode 3.25 3.25 3.25
(A) Normal mode 5.25 6.75 5.5 6.75 7.5
ECONO mode 2.5 2.5 2.5
SiENBE04-808_A.pdf 64 21/02/2011 13:19:56