Monitoring, Control and Alarm System
m2
Manual
Refrigeration and Air Conditioning Controls
R E F R I G E R A T I O N A N D A I R C O N D I T I O N I N G

Table of Contents

Other manuals for Danfoss m2

Question and Answer IconNeed help?

Do you have a question about the Danfoss m2 and is the answer not in the manual?

Danfoss m2 Specifications

General IconGeneral
BrandDanfoss
Modelm2
CategoryControl Systems
LanguageEnglish

Summary

Introduction

Safety Precautions

System Overview

Alarms

Details how the m2 provides audio and visual alarms for input exceeding preset levels.

Security Features

Explains security features like passcode access and fail-safe operation.

Battery Backup Functionality

Outlines the unit's battery backup for historical logging during power failure.

External Connections

Describes connections for sensors, controllers, and printers via RS232 and parallel ports.

Technical Data and Key Operation

Technical Specifications

Presents technical specifications of the m2 unit, including supply voltage, display, and inputs.

Key Operation Guide

Explains the functions of the keys on the m2 unit's front panel.

Alarm Mute and Menu Key Functions

Describes the main and secondary functions of the alarm mute and menu keys.

Key Pad Operation Guide

Print Key Functionality

Details the main and secondary functions of the print key for menu selection and case change.

Navigation and Selection Keys

Explains functions of Up, Down, Left, Right, and Enter keys for menu navigation and data entry.

Multiple Key Functions and Safety

Combined Key Press Functions

Details combined key presses for specific functions like backspace and screen contrast adjustment.

Operator and Equipment Safety

Emphasizes safe operation and maintenance procedures, including high voltage warnings.

Operation via the Key Pad

Point Overview Display

Explains how to view the status of all activated points on the m2 system.

Point Detail Display

Describes how to view detailed information for a specific point on the m2 system.

Point Configuration Options

Inhibiting a Point

Details how to temporarily disable a point to prevent alarms.

Point Offset Adjustment

Explains how to apply offsets to point readings for calibration or compensation.

Single Point Log Printout

Describes how to print log data for a single point from the m2.

Data Visualization

Graphics Display

Explains how to display and view historical data graphs for selected points.

Pulsed Input Functionality

Describes the pulsed input function for accepting pulses from a power meter.

Alarm Management

Muting and Clearing Alarms

Guides on how to stop the alarm siren and clear alarm conditions.

Main Menu Navigation

Explains how to navigate and select options within the m2's main menu.

Scan Mode Selection

Describes how to select and use different scan modes for viewing points.

History and Printing Options

Point Detail Scan Mode

Enables scanning mode for the Point Detail screen, cycling through points.

Alarm History Access

Explains how to access and view the historical list of alarms recorded by the m2.

Event History Access

Explains how to access and view the historical list of events recorded by the m2.

Print Menu Options

Describes how to access the print menu for various logging and graphing options.

Software and Time Settings

Software Version Information

Displays the m2 unit's software and hardware details for reference.

Setting System Time and Date

Guides on setting the system time, date, and daylight saving options.

Time and Date Configuration Details

Daylight Saving Setup

Details how to set automatic clock changes for winter/summer time.

Setup Information Printing

Explains how to print all configured setup information from the m2 unit.

System Configuration via Key Pad

Entering Characters in Edit Fields

Explains how to enter characters using the full and alphanumeric character sets.

Passcode and Installation Name Setup

Guides on entering the correct passcode and setting the installation name.

Point Configuration Details

Temperature Units and Date Format

Explains how to set temperature units and date format.

Point Setup and Type Selection

Guides on setting point details, number, and input type.

Point Input and Alarm Configuration

Input Units and Defrost Interlock

Details setting units of measurement and configuring defrost interlock points.

Alarm Settings and Actions

Guides on setting alarm limits, delays, and defining alarm actions.

Point Logging and Graphing Options

Log and Graph Action Settings

Guides on setting log and graph actions for points for printouts.

Point Setup Screen 2 Fields

Details additional fields like Input Source and Remote Address in point setup.

Input Types and Pulsed Input Setup

Input Type, Number, and Axis Settings

Covers input types, number, and graph axis settings for points.

4-20mA and Pulsed Input Configuration

Explains setup for 4-20mA inputs and pulsed inputs, including mode and Pls/kWh.

Data Export and Defrost Synchronization

Data Export and Pulsed Input Notes

Explains data export options and installation notes for pulsed inputs.

Defrost Synchronization Setup

Guides on setting up coordinated defrost for a network of EKC controllers.

Defrost, Password, and Frequency Settings

Defrost Control and Password Setup

Details defrost control options and password management for system access.

Log/Chart Frequency Settings

Guides on setting print frequencies for log and chart data.

Alarm Action Setup

Output Name and Action Triggers

Assigns names to output devices and sets trigger conditions for alarm actions.

Alarm Action Parameters

Alarm Delay, Duration, and Clearing

Defines delay, duration, and clearing methods for alarm actions.

Modem Dialout Options

Modem Dialout Configuration

Dialout Number and Call Type Selection

Specifies device type and telephone numbers for modem dialout.

Pager Info and Probe Curve Definition

Pager Info Text Codes

Explains how to add text codes to pager messages for additional information.

Probe Curve Table Setup

Guides on defining relationships between input values and engineering units using probe curves.

Curve Table Configuration Details

Curve Table Parameters

Details parameters like Curve, Break, Input, and Output for table setup.

Setting Up Curve Tables

Provides a step-by-step guide to completing the curve table for probe data.

Modem Configuration Settings

Baud Rate, Dial, Answer Codes, and Language

Configures modem settings and selects the unit's display language.

AKM Call Type and Dial Out Settings

AKM Call Type Background and Wiring

Explains AKM call type and details modem to m2 wiring.

Dial Out Settings and Modem Setup

Configures alarm actions for dial out and modem setup for AKM.

Maintenance and Character Sets

Maintenance Procedures

Provides instructions for cleaning and servicing the m2 unit.

Character Set Displays

Displays the available full and alphanumeric character sets.

Configuring m2+ via Key Pad

m2+ Point Configuration Details

Guides on setting up point type, input source, address, and input type for m2+ units.

EKC Controller Integration and Display

EKC Measurements and Setup Concept

Explains how the m2 displays data from EKC controllers and their setup.

EKC Controller Setup Process

EKC Controller Addressing and Setup

Details EKC controller addressing and the sequence for setup with the m2.

Displaying EKC Measurements

EKC Input Source and Parameter Selection

Guides on selecting input source and parameters for primary/secondary display from EKC controllers.

Alarm Action and Dial Out Configuration

Alarm Action Number Mapping and Triggers

Maps alarm action numbers to functions and defines trigger settings.

Modem Dial Out Settings

Configures modem dial-out settings, specifically for relay control.

Alarm and Dial Out Examples

Siren, Relay, and Dialout Examples

Illustrates activation examples for Siren, Relay, and Dialout based on alarm actions.

Modem Dialout BEEPER Example

Provides an example of modem dialout setup using the BEEPER call type.

List of Literature