6.3.21 33-** MCO Adv. Settings
Par.
No.
#
Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion
index
Type
33-0* Home Motion
33-00 Force HOME [0] Home not forced 2 set-ups TRUE - Uint8
33-01 Zero Point Offset from Home Pos. 0 N/A 2 set-ups TRUE 0 Int32
33-02 Ramp for Home Motion 10 N/A 2 set-ups TRUE 0 Uint32
33-03 Velocity of Home Motion 10 N/A 2 set-ups TRUE 0 Int32
33-04 Behaviour during HomeMotion [0] Revers and index 2 set-ups TRUE - Uint8
33-1* Synchronization
33-10 Sync Factor Master 1 N/A 2 set-ups TRUE 0 Int32
33-11 Sync Factor Slave 1 N/A 2 set-ups TRUE 0 Int32
33-12 Position Offset for Synchronization 0 N/A 2 set-ups TRUE 0 Int32
33-13 Accuracy Window for Position Sync. 1000 N/A 2 set-ups TRUE 0 Int32
33-14 Relative Slave Velocity Limit 0 % 2 set-ups TRUE 0 Uint8
33-15 Marker Number for Master 1 N/A 2 set-ups TRUE 0 Uint16
33-16 Marker Number for Slave 1 N/A 2 set-ups TRUE 0 Uint16
33-17 Master Marker Distance 4096 N/A 2 set-ups TRUE 0 Uint32
33-18 Slave Marker Distance 4096 N/A 2 set-ups TRUE 0 Uint32
33-19 Master Marker Type [0] Encoder Z positive 2 set-ups TRUE - Uint8
33-20 Slave Marker Type [0] Encoder Z positive 2 set-ups TRUE - Uint8
33-21 Master Marker Tolerance Window 0 N/A 2 set-ups TRUE 0 Uint32
33-22 Slave Marker Tolerance Window 0 N/A 2 set-ups TRUE 0 Uint32
33-23 Start Behaviour for Marker Sync [0] Start Function 1 2 set-ups TRUE - Uint16
33-24 Marker Number for Fault 10 N/A 2 set-ups TRUE 0 Uint16
33-25 Marker Number for Ready 1 N/A 2 set-ups TRUE 0 Uint16
33-26 Velocity Filter 0 us 2 set-ups TRUE -6 Int32
33-27 Offset Filter Time 0 ms 2 set-ups TRUE -3 Uint32
33-28 Marker Filter Configuration [0] Marker filter 1 2 set-ups TRUE - Uint8
33-29 Filter Time for Marker Filter 0 ms 2 set-ups TRUE -3 Int32
33-30 Maximum Marker Correction 0 N/A 2 set-ups TRUE 0 Uint32
33-31 Synchronisation Type [0] Standard 2 set-ups TRUE - Uint8
33-32 Feed Forward Velocity Adaptation 0 N/A 2 set-ups TRUE 0 Uint32
33-33 Velocity Filter Window 0 N/A 2 set-ups TRUE 0 Uint32
33-34 Slave Marker filter time 0 ms 2 set-ups TRUE -3 Uint32
33-4* Limit Handling
33-40 Behaviour at End Limit Switch [0] Call error handler 2 set-ups TRUE - Uint8
33-41 Negative Software End Limit -500000 N/A 2 set-ups TRUE 0 Int32
33-42 Positive Software End Limit 500000 N/A 2 set-ups TRUE 0 Int32
33-43 Negative Software End Limit Active [0] Inactive 2 set-ups TRUE - Uint8
33-44 Positive Software End Limit Active [0] Inactive 2 set-ups TRUE - Uint8
33-45 Time in Target Window 0 ms 2 set-ups TRUE -3 Uint8
33-46 Target Window LimitValue 1 N/A 2 set-ups TRUE 0 Uint16
33-47 Size of Target Window 0 N/A 2 set-ups TRUE 0 Uint16
Table 6.44