5.2.7 6-** Analog In/Out
Param
eter
numb
er
Parameter description Default value 4 set-up Change
during
operation
Conversion
index
Type
6-0* Analog I/O Mode
6-00 Live Zero Timeout Time 10 s All set-ups TRUE 0 Uint8
6-01 Live Zero Timeout Function [0] O All set-ups TRUE Uint8
6-1* Analog Input 1
6-10 Terminal 53 Low Voltage ExpressionLimit All set-ups TRUE -2 Int16
6-11 Terminal 53 High Voltage 10 V All set-ups TRUE -2 Int16
6-12 Terminal 53 Low Current 0.14 mA All set-ups TRUE -5 Int16
6-13 Terminal 53 High Current 20 mA All set-ups TRUE -5 Int16
6-14 Terminal 53 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
6-15 Terminal 53 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
6-16 Terminal 53 Filter Time Constant 0.01 s All set-ups TRUE -2 Uint16
6-2* Analog Input 2
6-20 Terminal 54 Low Voltage ExpressionLimit All set-ups TRUE -2 Int16
6-21 Terminal 54 High Voltage 10 V All set-ups TRUE -2 Int16
6-22 Terminal 54 Low Current ExpressionLimit All set-ups TRUE -5 Int16
6-23 Terminal 54 High Current 20 mA All set-ups TRUE -5 Int16
6-24 Terminal 54 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
6-25 Terminal 54 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
6-26 Terminal 54 Filter Time Constant 0.01 s All set-ups TRUE -2 Uint16
6-3* Analog Input 3
6-30 Terminal X30/11 Low Voltage 0.07 V All set-ups TRUE -2 Int16
6-31 Terminal X30/11 High Voltage 10 V All set-ups TRUE -2 Int16
6-34 Term. X30/11 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
6-35 Term. X30/11 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
6-36 Term. X30/11 Filter Time Constant 0.001 s All set-ups TRUE -3 Uint16
6-4* Analog Input 4
6-40 Terminal X30/12 Low Voltage 0.07 V All set-ups TRUE -2 Int16
6-41 Terminal X30/12 High Voltage 10 V All set-ups TRUE -2 Int16
6-44 Term. X30/12 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
6-45 Term. X30/12 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
6-46 Term. X30/12 Filter Time Constant 0.001 s All set-ups TRUE -3 Uint16
6-5* Analog Output 1
6-50 Terminal 42 Output ExpressionLimit All set-ups TRUE Uint8
6-51 Terminal 42 Output Min Scale 0 % All set-ups TRUE -2 Int16
6-52 Terminal 42 Output Max Scale 100 % All set-ups TRUE -2 Int16
6-53 Term 42 Output Bus Ctrl 0 % All set-ups TRUE -2 N2
6-54 Terminal 42 Output Timeout Preset 0 % 1 set-up TRUE -2 Uint16
6-55 Analog Output Filter [0] O 1 set-up TRUE Uint8
6-6* Analog Output 2
6-60 Terminal X30/8 Output ExpressionLimit All set-ups TRUE Uint8
6-61 Terminal X30/8 Min. Scale 0 % All set-ups TRUE -2 Int16
6-62 Terminal X30/8 Max. Scale 100 % All set-ups TRUE -2 Int16
6-63 Terminal X30/8 Bus Control 0 % All set-ups TRUE -2 N2
6-64 Terminal X30/8 Output Timeout Preset 0 % 1 set-up TRUE -2 Uint16