5-11 Terminal 19 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-12 Terminal 27 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-13 Terminal 29 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-14 Terminal 32 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-15 Terminal 33 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-16 Terminal X30/2 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-17 Terminal X30/3 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-18 Terminal X30/4 Digital Input ExpressionLimit All set-ups TRUE Uint8
5-3* Digital Outputs
5-30 Terminal 27 Digital Output ExpressionLimit All set-ups TRUE Uint8
5-31 Terminal 29 Digital Output ExpressionLimit All set-ups TRUE Uint8
5-32 Term X30/6 Digi Out (MCB 101) [0] No operation All set-ups TRUE Uint8
5-33 Term X30/7 Digi Out (MCB 101) [0] No operation All set-ups TRUE Uint8
5-4* Relays
5-40 Function Relay ExpressionLimit All set-ups TRUE Uint8
5-41 On Delay, Relay 0.01 s All set-ups TRUE -2 Uint16
5-42 O Delay, Relay 0.01 s All set-ups TRUE -2 Uint16
5-5* Pulse Input
5-50 Term. 29 Low Frequency 100 Hz All set-ups TRUE 0 Uint32
5-51 Term. 29 High Frequency ExpressionLimit All set-ups TRUE 0 Uint32
5-52 Term. 29 Low Ref./Feedb. Value 0 ReferenceFeedbackUnit All set-ups TRUE -3 Int32
5-53 Term. 29 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
5-54 Pulse Filter Time Constant #29 100 ms All set-ups FALSE -3 Uint16
5-55 Term. 33 Low Frequency 100 Hz All set-ups TRUE 0 Uint32
5-56 Term. 33 High Frequency ExpressionLimit All set-ups TRUE 0 Uint32
5-57 Term. 33 Low Ref./Feedb. Value 0 ReferenceFeedbackUnit All set-ups TRUE -3 Int32
5-58 Term. 33 High Ref./Feedb. Value ExpressionLimit All set-ups TRUE -3 Int32
5-59 Pulse Filter Time Constant #33 100 ms All set-ups FALSE -3 Uint16
5-6* Pulse Output
5-60 Terminal 27 Pulse Output Variable ExpressionLimit All set-ups TRUE Uint8
5-62 Pulse Output Max Freq #27 ExpressionLimit All set-ups TRUE 0 Uint32
5-63 Terminal 29 Pulse Output Variable ExpressionLimit All set-ups TRUE Uint8
5-65 Pulse Output Max Freq #29 ExpressionLimit All set-ups TRUE 0 Uint32
5-66 Terminal X30/6 Pulse Output Variable [0] No operation All set-ups TRUE Uint8
5-68 Pulse Output Max Freq #X30/6 5000 Hz All set-ups TRUE 0 Uint32
5-7* 24V Encoder Input
5-70 Term 32/33 Pulses Per Revolution 1024 N/A All set-ups FALSE 0 Uint16
5-71 Term 32/33 Encoder Direction [0] Clockwise All set-ups FALSE Uint8
5-9* Bus Controlled
5-90 Digital & Relay Bus Control 0 N/A All set-ups TRUE 0 Uint32
5-93 Pulse Out #27 Bus Control 0 % All set-ups TRUE -2 N2
5-94 Pulse Out #27 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
5-95 Pulse Out #29 Bus Control 0 % All set-ups TRUE -2 N2
5-96 Pulse Out #29 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
5-97 Pulse Out #X30/6 Bus Control 0 % All set-ups TRUE -2 N2
5-98 Pulse Out #X30/6 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
Parameter Lists Programming Guide
MG06J202 Danfoss A/S © 03/2019 All rights reserved. 165