5.2.13 14-** Special Functions
Param
eter
numb
er
Parameter description Default value 4 set-up Change
during
operation
Conversion
index
Type
14-0* Inverter Switching
14-00 Switching Pattern [1] SFAVM All set-ups TRUE – Uint8
14-01 Switching Frequency ExpressionLimit All set-ups TRUE – Uint8
14-03 Overmodulation ExpressionLimit All set-ups FALSE – Uint8
14-04 Acoustic Noise Reduction [0] O All set-ups TRUE – Uint8
14-06 Dead Time Compensation [1] On All set-ups TRUE – Uint8
14-1* Mains Failure
14-10 Mains Failure [0] No function All set-ups TRUE – Uint8
14-11 Mains Fault Voltage Level ExpressionLimit All set-ups TRUE 0 Uint16
14-12 Response to Mains Imbalance [0] Trip All set-ups TRUE – Uint8
14-14 Kin. Back-up Time-out 60 s All set-ups TRUE 0 Uint8
14-15 Kin. Back-up Trip Recovery Level ExpressionLimit All set-ups TRUE -3 Uint32
14-16 Kin. Back-up Gain 100 % All set-ups TRUE 0 Uint32
14-2* Trip Reset
14-20 Reset Mode [0] Manual reset All set-ups TRUE – Uint8
14-21 Automatic Restart Time ExpressionLimit All set-ups TRUE 0 Uint16
14-22 Operation Mode [0] Normal operation All set-ups TRUE – Uint8
14-24 Trip Delay at Current Limit 60 s All set-ups TRUE 0 Uint8
14-25 Trip Delay at Torque Limit 60 s All set-ups TRUE 0 Uint8
14-26 Trip Delay at Inverter Fault ExpressionLimit All set-ups TRUE 0 Uint8
14-3* Current Limit Ctrl.
14-30 Current Lim Ctrl, Proportional Gain 100 % All set-ups FALSE 0 Uint16
14-31 Current Lim Ctrl, Integration Time ExpressionLimit All set-ups FALSE -3 Uint16
14-32 Current Lim Ctrl, Filter Time ExpressionLimit All set-ups TRUE -1 Uint16
14-4* Energy Optimising
14-40 VT Level 66 % All set-ups FALSE 0 Uint8
14-41 AEO Minimum Magnetisation ExpressionLimit All set-ups TRUE 0 Uint8
14-42 Minimum AEO Frequency ExpressionLimit All set-ups TRUE 0 Uint8
14-43 Motor Cosphi ExpressionLimit All set-ups TRUE -2 Uint16
14-5* Environment
14-50 RFI Filter [1] On 1 set-up FALSE – Uint8
14-51 DC-Link Compensation ExpressionLimit All set-ups TRUE – Uint8
14-52 Fan Control [0] Auto All set-ups TRUE – Uint8
14-53 Fan Monitor [1] Warning All set-ups TRUE – Uint8
14-55 Output Filter [0] No Filter All set-ups FALSE – Uint8
14-59 Actual Number of Inverter Units ExpressionLimit 1 set-up FALSE 0 Uint8
14-6* Auto Derate
14-60 Function at Over Temperature [0] Trip All set-ups TRUE – Uint8
14-61 Function at Inverter Overload [0] Trip All set-ups TRUE – Uint8
14-62 Inv. Overload Derate Current 95 % All set-ups TRUE 0 Uint16
14-8* Options
14-89 Option Detection [0] Protect Option Cong. 1 set-up TRUE – Uint8
14-9* Fault Settings
14-90 Fault Level ExpressionLimit 1 set-up TRUE – Uint8