0-20 Display Line 1.1 Small
Option: Function:
[1635] Inverter Thermal Percentage load of the inverters.
[1636] Inv. Nom. Current Nominal current of the frequency
converter.
[1637] Inv. Max. Current Maximum current of the frequency
converter.
[1638] SL Controller State State of the event executed by the
control.
[1639] Control Card Temp. Temperature of the control card.
[1644] Speed Error [RPM]
[1645] Motor Phase U
Current
[1646] Motor Phase V
Current
[1647] Motor Phase W
Current
[1648] Speed Ref. After
Ramp [RPM]
[1650] External Reference Sum of the external reference as a
percentage, that is the sum of
analog/pulse/bus.
[1651] Pulse Reference Frequency in Hz connected to the
digital inputs (18, 19 or 32, 33).
[1652] Feedback[Unit] Reference value from programmed
digital inputs.
[1653] Digi Pot Reference
[1657] Feedback [RPM]
[1660] Digital Input Signal states from the 6 digital
terminals (18, 19, 27, 29, 32, and
33). There are 16 bits in total, but
only 6 of them are used. Input 18
corresponds to the far left of the
used bits. Signal low = 0; Signal
high = 1.
[1661] Terminal 53 Switch
Setting
Setting of input terminal 54.
Current = 0; Voltage = 1.
[1662] Analog Input 53 Actual value at input 53 either as a
reference or protection value.
[1663] Terminal 54 Switch
Setting
Setting of input terminal 54.
Current = 0; Voltage = 1.
[1664] Analog Input 54 Actual value at input 54 either as
reference or protection value.
[1665] Analog Output 42
[mA]
Actual value at output 42 in mA.
Use parameter 6-50 Terminal 42
Output to select the value to be
shown.
[1666] Digital Output [bin] Binary value of all digital outputs.
[1667] Freq. Input #29
[Hz]
Actual value of the frequency
applied at terminal 29 as an
impulse input.
[1668] Freq. Input #33
[Hz]
Actual value of the frequency
applied at terminal 33 as an
impulse input.
[1669] Pulse Output #27
[Hz]
Actual value of impulses applied to
terminal 27 in digital output mode.
0-20 Display Line 1.1 Small
Option: Function:
[1670] Pulse Output #29
[Hz]
Actual value of impulses applied to
terminal 29 in digital output mode.
[1671] Relay Output [bin]
[1672] Counter A Application-dependent (for
example SLC control).
[1673] Counter B Application-dependent (for
example SLC control).
[1675] Analog In X30/11 Actual value at input X30/11 either
as reference or protection value.
[1676] Analog In X30/12 Actual value at input X30/12 either
as reference or protection value.
[1677] Analog Out X30/8
[mA]
Actual value at output X30/8 in
mA. Use parameter 6-60 Terminal
X30/8 Output to select the value to
be shown.
[1678] Analog Out X45/1
[mA]
[1679] Analog Out X45/3
[mA]
[1680] Fieldbus CTW 1 Control word (CTW) received from
the bus master.
[1682] Fieldbus REF 1 Main reference value sent with
control word from the bus master.
[1684] Comm. Option STW Extended eldbus communication
option status word.
[1685] FC Port CTW 1 Control word (CTW) received from
the bus master.
[1686] FC Port REF 1 Status word (STW) sent to the bus
master.
[1687] Bus Readout
Alarm/Warning
[1690] Alarm Word 1 or more alarms in a hex code.
[1691] Alarm Word 2 1 or more alarms in a hex code.
[1692] Warning Word 1 or more warnings in a hex code.
[1693] Warning Word 2 1 or more warnings in a hex code.
[1694] Ext. Status Word 1 or more status conditions in a
hex code.
[1695] Ext. Status Word 2 1 or more status conditions in a
hex code.
[1697] Alarm Word 3 1 or more alarms in a hex code.
[1698] Warning Word 3 1 or more warnings in a hex code.
[1890] Process PID Error
[1891] Process PID Output
[1892] Process PID
Clamped Output
[1893] Process PID Gain
Scaled Output
[2117] Ext. 1 Reference
[Unit]
[2118] Ext. 1 Feedback
[Unit]
[2119] Ext. 1 Output [%]
Parameter Descriptions VLT® AutomationDrive FC 361