4.1.6 Connector Pin Assignment
Table 8: Connector Pin Assignment, VLT® Safety Option MCB 150
Y30 Pin Name Description
1 2 3 4 5 6 7 8 9 10 11 12
e30bc315.11
1 DI1 A Digital input 1 A channel
2 GND Digital GND
3 DI1 B Digital input 1 B channel
4 ENC A Encoder channel A
5 DI2 A Digital input 2 A channel
6 ENC nA Encoder channel A inverted
7 ENC B Encoder channel B
8 DI2 B Digital Input 2 B channel
9 ENC nB Encoder channel B inverted
10 24 V Power output
11 GND Supply GND
12 S37 STO enable
e30bc325.12
MCB 150
Safe Option
SW. ver. xx. xx
Option B
130B3280
LED:
1
2
3 4
TTL Enc.
interface
Y30/
DI1 A
GND
DI1 B
ENC A
DI2 A
ENC nA
ENC B
DI2 B
ENC nB
24V
GND
S37
1
2
3
4
5 6
7
8
9
10
11 12
Illustration 22: Nameplate MCB 150