• General speed monitoring.
• Safe input.
• Safe Stop 1.
• Safely Limited Speed.
• Parameters.
• Status.
The menu items are described in detail in the VLT® Motion Control Tool MCT 10 Operating Guide.
The menu item Status shows the following:
• Current signal states of inputs and outputs.
• Option operating mode
• Active safety function.
The states of the inputs and output cannot be changed via the commissioning software.
6.1.3 Password Protection
Use a password to protect the system configuration. A password must be entered only when changing safety option parameters
(writing to option).
Default password is 12345678.
It is advised to change the safety option default password before downloading the parameter values of a safety option with factory
settings. Only persons knowing the password can change the safety option parameter values.
NOTICE
Any misuse of password may lead to severe safety problems.
NOTICE
No password is required to access the commissioning parameters of the safety option. The password is required when the
parameters must be downloaded to the option via Write to Drive.
The password must be of 8 characters and is case-sensitive. Alphanumeric characters and symbols are valid for password.
The safety option checks the parameter password entered. Use the menu item Change Password to change the safety option
parameter password. Change the safety option password if there is any indication of manipulation.