Group Group
name
Parameter Value range/
available op-
tions
Default Description Con-
ver-
sion
index
Data
type
42-4* SS1 42-40 Type [0] Delay [0] Delay The type of the SS1 Safety Function. u_int8
[1] Ramp
(slope)
[2] Ramp (time)
42-41
Ramp Pro-
file
[0] Linear [0] Safe Op-
tion Linear
The ramp profile for an SS1 Delay can
be either specified as linear or S-ramp.
u_int8
[2] S-ramp
Const Time
42-42 De-
lay Time
0.1–3600.0 s 1.0 s Time until STO is activated -1 u_int16
42-43 Delta
T
0–99% 2% Δ T subtracts from the time in parame-
ter 42-42 Delay Time to get motor to
stop before the timer expires.
0 u_int8
42-44 De-
celeration
Rate
1–30000 RPM/s 1500 RPM/s Deceleration rate for the SS1 slope-
based ramp type.
0 u_int16
42-45 Delta
V
1–10000 RPM 120 RPM Tolerance between calculated and ac-
tual speed that the safety option al-
lows.
67 u_int16
42-46 Zero
Speed
1–600 RPM 10 RPM When this speed is reached, the safety
option activates the STO.
67 u_int16
42-47
Ramp Time
0.1–3600.0 s 1.0 s Time to ramp down to 0 RPM -1 u_int16
42-48 S-
ramp Ratio
at Decel.
Start
1 to (100 -
42-49 S-ramp
Ratio at Decel.
End)%
50% The proportion of the total ramp-down
time (parameter 42-42 Delay Time)
where the deceleration torque increa-
ses. The larger the percentage value,
the greater the jerk compensation ach-
ieved, and thus the lower the torque
jerks in the application.
0 u_int8
42-49 S-
ramp Ratio
at Decel.
End
1 to (100 -
42-48)%
50% The proportion of the total ramp-down
time (parameter 42-42 Delay Time)
where the deceleration torque decrea-
ses. The larger the percentage value,
the greater the jerk compensation ach-
ieved, and thus the lower the torque
jerks in the application.
0 u_int8
General Parameter Set-up
Installation Guide | VLT® Safety Option MCB 150/151
AQ279747441421en-000101 / 130R0292 | 65
Danfoss A/S © 2018.09

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Safety Option MCB 150 and is the answer not in the manual?

Danfoss VLT Safety Option MCB 150 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Safety Option MCB 150
CategoryControl Unit
LanguageEnglish

Related product manuals