EasyManuals Logo

Danfoss VLT Safety Option MCB 150 User Manual

Danfoss VLT Safety Option MCB 150
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
Table 36: Safety Function
IEC 61800-5-2 IEC 60204-1
Safe Torque Off (STO) Stop Category 0
Safe Stop 1 (SS1) Stop Category 1
Safely Limited Speed (SLS)
Table 37: Safety Performance
Name of performance Type/description
Safety Integrity Level SIL 2
SIL CL2
HFT (IEC 61508) Hardware Fault Tolerance = 1
Subsystem classification Type B
Probability of dangerous failure per hour PFH: 1,52 e-8
Probability of dangerous failure on demand PFD: 1,33 e-3
Category Cat 3
Performance level PL d (cat 3)
Mean time to dangerous failure of each channel MTTFd: 245 years (High)
Average diagnostic coverage DC
ave
: 86% (Low)
Safe failure fraction SFF: 90%
Proof test interval 20 years
Technical Specifications
Installation Guide | VLT® Safety Option MCB 150/151
AQ279747441421en-000101 / 130R0292 | 95
Danfoss A/S © 2018.09

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Safety Option MCB 150 and is the answer not in the manual?

Danfoss VLT Safety Option MCB 150 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Safety Option MCB 150
CategoryControl Unit
LanguageEnglish

Related product manuals