Page 44 of 56
3.3.5.5. SW Commands
The following are the commands for the standard software listed in alphabetical order.
Please see the SW appendix for detailed explanation of each command.
STANDARD COMMANDS (summary)
AD X Read value from an ADC channel.
ADR Read the address of the MPS.
ADR XXX Write an address to a MPS.
ANACTRL MPS Control by analogue Set.
ASW Enters Answer mode.
CMD Read current control mode.
CMDSTATE Read current control state.
CPUCTRL MPS Control by CPU DAC.
DA X XXXXXX Writes a value to a Digital to Analog
converter. (Alternative to the WA
command).
ERRC Coded error message.
ERRT Text string error message.
F Main Power OFF.
LALL Listen ALL.
LOC Change to Local Control.
LOCK Lock the MPS in Local Control.
N Main Power ON.
NASW No answer mode.
NERR No error message.
PO Polarity status.
PO +/- Change to Normal polarity.
POLOOL Polarity Output Off Limit.
PRINT Reads internal user information about
the MPS.
RA Read the set value.
REM Change to remote control.
RLOCK Remote line only.
RR Read Ramp speed.
RS Reset interlocks.
S1 Read the internal status.
S1H Read internal status in HEX format.
S1FIRST Read the interlock first catch status.
S1FIRSTH Read the interlock f
in HEX format
S3 Read the internal extended status.
S3H Read internal extended status in HEX
format.
TD Test DAC.
TYPE AD type in use.
UNLOCK Unlock the MPS.
VER Reads the software version.
WA XXXXXX Writes a value to a Digital to Analog
converter.
(Preferred new command: DA 0)
WR Write Ramp speed.
X is a number from 0 to 9 and Commands in quotation marks are optional.