SR200 & SR300 Card Printers and LM200 & LM300 Laminators Users Guide B-5
Operating Environment Conditions
Storage Environment Conditions
Laminator Specifications
Te mperature: 59°–86°F(15°–30°C)
Humidity 35%–70%(withoutcondensation)
Temperature 5°–131°F(15°–55°C)
Humidity 20%–80%(withoutcondensation)
Transfermethod Halogenlamp,builtinhea trollermethod
Transfertime About20seconds,dependingonsettingsused
Powersupply: 100–120VACor220–240V AC(±10%)
Powerconsumption Approximately190W
Weight LM200:17.6lbs(8kg)
LM300:19.8lbs(9kg)
Soundlevel Lessthan70dB(A)accordingtoDIN45635,part19
(EN27779).