EasyManuals Logo

Datakom D Series User Manual

Datakom D Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
D-500L Firmware V-5.8
K35D03-EN - 90 -
Parameter Definition
Unit
Min
Max
Factory
Set
Description
Coolant Cooler On
°C
0
250
90
If the coolant temp is above this limit then
the cooler relay function will become
active.
Coolant Cooler Off
°C
0
250
80
If the coolant temp is below this limit then
the cooler relay function will become
inactive.
Coolant Heater On
°C
0
250
50
If the coolant temp is below this limit then
the heater relay function will become
active.
Coolant Heater Off
°C
0
250
60
If the coolant temp is above this limit then
the heater relay function will become
inactive.
Fan Overrun Timer
sec
0
240
0
The cooler relay will stay active during
this timer after the coolant temp is below
“Coolant Cooler Off” limit.
Canopy Fan Turn-On
°C
0
250
90
If the canopy temp is above this limit then
the canopy fan relay function will become
active.
Canopy Fan Turn-Off
°C
0
250
80
If the canopy temp is below this limit then
the canopy fan relay function will become
inactive.
Ambient Fan Turn-On
°C
0
250
90
If the ambient temp is above this limit
then the ambient fan relay function will
become active.
Ambient Fan Turn-Off
°C
0
250
80
If the ambient temp is below this limit
then the ambient fan relay function will
become inactive.
Service-1 Engine Hours
hours
0
5000
250
The SERVICE REQUEST led indicator
will turn on after this quantity of engine
hours from the last service. If the period
is set to ‘0’ no SERVICE REQUEST will
be generated depending on service-1
engine hours.
Service-1 Period
month
0
24
6
The SERVICE REQUEST led indicator
will turn on after this amount of time
from the last service. If the period is set
to ‘0’ no SERVICE REQUEST will be
indicated depending on Service-1
Period.
Service-1 Alarm Level
-
0
3
3
0: no action
1: shutdown alarm
2: loaddump alarm
3: warning
16.3. ENGINE PARAMETERS GROUP (continued)