Enter/Exit Programming Mode
92 Gryphon™ I GD/GBT/GM4500
Transmit Labels in code 39 Format
This feature enable/disables translation to Code 39 before transmitting label 
data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is mod-
ified for the translation. The data is not converted to Code 
39 or verified to be 
valid for Code 39.
Options are:
IBM Standard Format: 
Send labels in standard IBM format.
Code 39 Format: 
Translate the following symbologies to Code 39:
• USB-OEM: Code128, Code 93, and Codabar
• IBM-Port 5B: Code 128, Code 93, and C
odabar
• IBM-Port 9B: Code 93 and Codabar
DEFAULT
Transmit Labels in Code 39 Format = 
IBM Standard Format
Transmit Labels in Code 39 Format = Code 39 Format
Interface Options
Obey Scanner Configuration Host Commands
Ignore Scanner Configuration Host Commands
This feature provides for an interface-specific control mechanism.