Wireless Features Enter/Exit Programming Mode
Product Reference Guide 255
Configuration Updates
See page 259 in “References” for detailed information and examples of these
features.
Automatic Configuration Update
When this feature is enabled, a reader and its linked Base Station can automati-
cally ensure they stay in sync with rega
rd to application hardware and/or con-
figuration. See
page 259 for more information
on this feature.
Automatic Configuration Update = Disable
Automatic Configuration Update = Enable
DEFAULT
Copy Configuration to Scanner
Scan the following label to copy the current Base Station configuration to the
scanner. Use this method when the Auto Configuration Update feature is dis-
abled and you want a one-time configuration
update to be performed on the
scanner.
NOTE
Copy Configuration to Scanner
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunc-
tion with this bar code.