References
282 Gryphon™ I GD/GBT/GM4500
Keyboard Interface
Wedge Quiet Interval
Specifies the amount of time the scanner looks for keyboard activity before it 
breaks the keyboard connection in order to transmit data to host. The range is 
from 0 to 990ms in 10ms increments.
NOTE
This feature applies ONLY to the Keyboard Wedge interface.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the 
r
esult with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 
20 = 20, etc.
3. Go to 
page 82
 and scan the ENTER/EXIT PROGRAMMING MODE bar code to 
enter Prog. Mode.
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING on 
page 82
.
5. Scan the appropriate two digits from the keypad in 
Appendix D, Keypad
, that 
represent the duration which was determined in the steps above. You will 
hear
 a two-beep indication after the last character.
NOTE
If you make a mistake before the last cha
racter, scan the CANCEL bar code 
to abort and not save the entry string. You can then start again at the 
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wedge Quiet Interval. See the table 
below for 
examples of how to set this feature.
Table 12. Wedge Quiet Interval Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
10ms 150ms 600ms 850ms
2 
Divide by 10 (and pad with 
leading zeroes)
01 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT WEDGE QUIET INTERVAL SETTING
5
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE