1D Symbologies Enter/Exit Programming Mode
Product Reference Guide 179
Codabar Check Character Transmission
Enable this option to transmit the check character along with Codabar bar code
data.
NOTE
Codabar Check Character Transmission = Don’t Send
Codabar Check Character Transmission = Send
DEFAULT
This feature is valid only when Codabar Check Character Calculation is
enabled.
Codabar Start/Stop Character Transmission
Enable this option to enable/disable transmission of Codabar start and stop
characters
Codabar Start/Stop Character Transmission = Don’t Transmit
Codabar Start/Stop Character Transmission = Transmit
DEFAULT
.
$CCBCT00
$CCBCT01
$CCBSS00
$CCBSS01