EasyManua.ls Logo

Datamax A-4310 - STX Kp Module Protection

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extended System-Level Command Functions
96 Class Series Programmer’s Manual
STX Kp Module Protection
(Display-Equipped Models only)
This command controls memory module protection. When “protected”, a module will ignore format,
downloads and delete commands. This command can be useful to add data to Datamax reserved
modules, Z (ILPC) and Y (EFIGS). See Appendix K for a listing of the memory modules.
There are two types of modules: RAM (volatile) and Flash (non-volatile).
RAM - When protected, if the power is cycled or if the printer is reset, the module state resets
back to unprotected.
Flash - When protected, the module can be temporarily unprotected. However, if the power is
cycled or if the printer is reset, the module is initialized to ‘protected.’
Syntax:
<STX>Kpmf
Where:
m
- Module ID – Range A to Z (See Appendix K).
Where:
f
- Flag specifying Enable or Disable protection.
0 = disable protection
1 = enable protection
Sample:
<STX>KpY0
This example disables protection for memory module “Y”. Graphics may now be downloaded to
module “Y” and, on subsequent resets, these graphics will be protected.

Table of Contents

Related product manuals