Appendix L – Speed Ranges
244 Class Series Programmer’s Manual
Print Speed Feed Speed Reverse Speed Slew Speed (GPIO)
Model
Range Default Range Default Range Default Range Default
A-4212
C – W O C – W O C – I G C – a O
A-4310
C – S O C – W O C – I G C – a O
A-4408
C – O K C – S K C – I
G C – a K
A-4606
C – K G C – O G C – I
G C – a G
A-6212
C – W O C – W O C – I
G C – Y O
A-6310
C – S O C – W O C – I
G C – Y O
E-4203
[1]
A – G G A – G G A – E C N/A N/A
E-4204
A – G G A – G G A – E C N/A N/A
E-4304
A – G G A – G G A – E C N/A N/A
EX2
A – G G A – G G A – E C N/A N/A
H-4212 &
H-4212X
C – W O C – W O C – G G C – a O
H-4310 &
H-4310X
C – S O C – W O C – G G C – a O
H-4408
C – O K C – S K C – G G C – a K
H-4606 &
H-4606X
C – K G C – O G C – G G C – a G
H-6210
C – S K C – W K C – G G C – W K
H-6212X
C – W O C – W O C – G G C – Y O
H-6308
C – O K C – S K C – G G C – S K
H-6310X
C – S O C – W O C – G G C – Y O
H-8308X
C – O K C – S K C – G G C – W K
I-4206
C – K K C – O K C – G G C – K K
I-4208
C – O O C – O O C – G G C – O O
I-4210
C – S O C – S O C – G G C – W O
I-4212
C – W O C – W O C – G G C – W O
I-4308
C – O K C – O K C – G G C – O K
I-4406
C – K I C – K I C – G G C – K I
I-4604
C – G E C – G E C – G G C – G E
M1
C – K K C – K K C – G G C – K K
M2
C – S O C – S O C – G G C – S O
M-4206
C – K G C – K G C – G C C – K G
M-4208
C – O O C – O O C – G G C – O O
M-4306
C – K G C – K G C – G C C – K G
W-6208
C – O K C – S K C – G G C – S K
W-6308
C – O K C – S K C – G G C – S K
W-8306
C – K K C – O K C – G G C – O K
[1]
Maximum speed is limited to ‘E’ unless the optional regulated power supply is attached.
Table L-2: Speed Ranges and Defaults