EasyManuals Logo

Datamax A-4310 User Manual

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Extended System-Level Command Functions
44 Class Series Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Print Control
Non-Display 28
Column Adjust
[
1]
CA
xxx dots
Resolution specific;
see Appendix K,
and see
Column Adjust Fine
Tune
M1 & M2
Non-Display
7
N/A
Display-Equipped Print Control
Column Adjust Fine Tune
CF
+ / – dots
Resolution specific;
see Appendix K.
EX2 N/A
N/A
Display-Equipped Print Control
Column Offset
CO
0 – 9999 1/100 in.
EX2 N/A
Cnnnn
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Non-Display 26
Comm Heat Commands
CH
1, 0
1 = Enabled,
0 = Disabled
M1 & M2
Non-Display
25
N/A
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Non-Display 25
Comm Speed Commands
CS
1, 0
1 = Enabled,
0 = Disabled
M1 & M2
Non-Display
26
N/A
Table 5-1: Configuration Set Commands (continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-4310 and is the answer not in the manual?

Datamax A-4310 Specifications

General IconGeneral
BrandDatamax
ModelA-4310
CategoryPrinter
LanguageEnglish

Related product manuals