Loading...
Extended System-Level Command Functions
44 Class Series Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Print Control
Non-Display 28
Column Adjust
[
1]
CA
xxx dots
Resolution specific;
see Appendix K,
and see
Column Adjust Fine
Tune
M1 & M2
Non-Display
7
N/A
Display-Equipped Print Control
Column Adjust Fine Tune
CF
+ / – dots
Resolution specific;
see Appendix K.
EX2 N/A
N/A
Display-Equipped Print Control
Column Offset
CO
0 – 9999 1/100 in.
EX2 N/A
Cnnnn
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Non-Display 26
Comm Heat Commands
CH
1, 0
1 = Enabled,
0 = Disabled
M1 & M2
Non-Display
25
N/A
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Non-Display 25
Comm Speed Commands
CS
1, 0
1 = Enabled,
0 = Disabled
M1 & M2
Non-Display
26
N/A
Table 5-1: Configuration Set Commands (continued)