Extended System-Level Command Functions
54 Class Series Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Print Control
Present Distance
PD
0 – 400 1/100 inch
EX2
[4]
N/A
<STX>Kf
Display-Equipped Printer Options
A/Y, E, N/D
A or Y = Auto,
E = Enabled,
N or D = Disabled
M1 & M2
Non-Display
<STX>V
Present Sensor Equipped
PS
A, Y, N
A = Auto,
Y = Enabled,
N = Disabled
Non-Display
3
<STX>V,
<STX>KD
Display-Equipped Print Control
Print Contrast
PC
0 – 64 N/A
Non-Display N/A
N/A
Display-Equipped System Settings
Printer Level
PL
000000 –
FFFFFF
Hex Codes
EX2 N/A
N/A
Display-Equipped Print Control
Print Speed
pS
Alpha
character
Model specific ranges;
see Appendix L.
EX2 N/A
Pa
Query Configuration
QQ
Q, K N/A All Configuration Label N/A
Reflective No Paper
[2]
Minimum (Out Of Stock)
RN
0 – 16 .1 Volt DC
Non-Display (except
M1 & M2)
11 N/A
Table 5-1: Configuration Set Commands (continued)