Extended System-Level Command Functions
Class Series Programmer’s Manual 57
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
SOP Adjust
[1]
SA
0 – 255
(128
nominal)
N/A,
see Row Adjust Fine
Tune
Non-Display (except
M1 & M2)
5
<STX>O
Display-Equipped System Settings
SOP Emulation
SE
A, L, P, D
A = Allegro,
L = Prodigy Plus,
P = Prodigy,
D = Disable
EX2 N/A
N/A
Display-Equipped
Save As Filename
SF
Alphanumeric
string
Up to 16 characters
EX2
System Settings N/A
Display-Equipped System Settings
100 – 8192 Kbytes
M1 & M2
Non-Display
14
N/A
Scalable Font Cache
SC
0 – 128 4 Kbytes (0 = disabled) Non-Display 16
<STX>KS
Display-Equipped
Scalable Heap
SH
0 – 9999 Kbytes
EX2
N/A N/A
Scanner Configuration
SN
C, H, M,
D, B, V
See Table 5-11. Display-Equipped Printer Options N/A
Table 5-1: Configuration Set Commands (continued)