Extended System-Level Command Functions
64 Class Series Programmer’s Manual
(CH) Communicated Heat Commands – This command causes the printer to ignore DPL Heat
commands; instead, the Heat value is controlled via the menu setting.
(CL) Continuous Label Length – See <STX>c for command details.
(CO) Column Offset – See Cnnnn for command details.
(CS) Communicated Speed Commands – This command causes the printer to ignore DPL speed
commands; instead, speed values are controlled via the menu setting.
(CT) Communicated TOF Commands – This command causes the printer to ignore DPL TOF
(Gap, Continuous, and Reflective) commands; instead, the sensor type is controlled via the menu
setting.
(DE) DPI Emulation – This command allows printers with higher resolutions to emulate lower
print resolutions, as follows:
600 DPI can emulate 300 and 203 DPI resolutions
400 DPI can emulate a 203 DPI resolution
(DK) Darkness – This command controls the print head strobe timing to fine-tune the HEAT
setting.
(DM) Default Module – See <STX>X for command details.
(DR) Delay Rate – This command sets the number of minutes to delay between multiple batch
printings of Quick Test Labels.
(DS) Double Byte Symbol Set – See <STX>y or ySxx for command details.