44 A-Class
Printer Options (continued)
Menu Item Details
TAG TYPE Selects the UHF tag type, where:
EPC 0
EPC 0+ MATRICS
EPC 0+ IMPINJ
EPC 1
EM 4022/1222
GEN 2
Is the selected type.
TAG DATA SIZE
Selects the tag data size, where:
96-BIT Sets a 96-bit data size.
64-BIT Sets a 64-bit data size.
POWER ADJUST (dBm)
Adjusts the applied power, where:
000 (-04 Æ 04)
Is the power level, in 1.0 dBm increments.
KILL CODE
Sets the code to permanently deactivate the tag,
where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
ACCESS CODE
Sets the code to protect tag memory contents, where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
GEN 2 LOCK ACTION
Sets the lock for Gen 2 tags, where:
NONE
Does not lock the tag.
PERMALOCK
Locks data permanently.
PWD-READ/WRITE
Locks data with password-protection for writing data.
BOTH
Allows both Permalock and PWD-Lock to be used.
PAD/TRUNC. EPC DATA
Allows padding or truncating of data with nulls
(represented as “00”) in order to fit the selected EPC
Tag Data Size, where:
DISABLED
Does not pad or truncate data.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-Class A-6310 and is the answer not in the manual?

Datamax A-Class A-6310 Specifications

General IconGeneral
BrandDatamax
ModelA-Class A-6310
CategoryLabel Maker
LanguageEnglish

Related product manuals