62 A-Class
Communications (continued)
Menu Item Details
STX-V SW SETTINGS
Determines how a host option enable command is
handled, where:
ENABLED
Processes the command normally.
DISABLED
Controls the settings via the menu; see Section 4.2.3.
MAX LENGTH COMMAND
Determines how a host Maximum Label Length
(<STX>M) command is handled, where:
ENABLED
Processes the command normally.
DISABLED
Controls the setting via the menu; see Section 4.2.1.
OPTION FEEDBACK
Allows feedback characters from an optional device to
be returned to the host device, in the format of
<A;B;C;D;E;F>[CR], where:
A - Is the device type: R = RFID; and, S = Linear Scanner
B - Is the status: C = entire label complete; F = faulted
(failed) label; and, U = unknown
C - Is the number of expected reads, given in two
characters.
D - Is the number of good reads, given in two characters.
E - Is the internal Job and Sub Job Identifier, given in four
characters each.
F - Is the data read, delimited with semicolons (;) if
multiple reads.
DISABLED
Reports no data.
SCANNER
Reports Linear Scanner data.
RFID HEX
Reports RFID data in hexadecimal format.
RFID ASCII
Reports RFID data in an ASCII format.
PROCESS SOH (DATA)
Determines the response to an Immediate Command
(e.g., Get Status, Module Storage, etc.), where:
ENABLED
Interrupts operations upon SOH receipt to process the
command.
DISABLED
Processes commands normally.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-Class A-6310 and is the answer not in the manual?

Datamax A-Class A-6310 Specifications

General IconGeneral
BrandDatamax
ModelA-Class A-6310
CategoryLabel Maker
LanguageEnglish

Related product manuals