EasyManua.ls Logo

Deger MLD Control - Central Control Box (CCB); CCB: Pin Assignment

Deger MLD Control
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
01/10/2021 ASSEMBLY INSTRUCTIONS MLD Control EC-6 with CCB III Page 12
3 Central Control Box (CCB)
3.1 CCB: Pin assignment
The clamping area on the cable fitting is designed for a cable cross-section of 3.5 mm to 7 mm.
Terminal
Function
Terminal
Function
20
Input (incline) DC 21 V
for snow sensor
A - B V
in
Input supply voltage
- DC 80 to 380 V
- AC 100 to 265 V
21
N/A
1 - 2
Output for EC-6 DC +/-21 V
EL axis
22
Input
from wind monitor
Wire Green
3 - 4
Output for EC-6 DC +/-21 V
AZ axis
23
Broken Wire Detection from Wind Monitor
GND
N/A
+ / -
Voltage supply DC 21 V, max. 1.4 A
for snow sensor and wind monitor
Red Wire of Wind Monitor
WH
N/A
2
1
2
0
2
2
2
3
Relay for
wind
monitor
Basic
(only for
CCB II)
open
open
open
open