01/10/2021 ASSEMBLY INSTRUCTIONS MLD Control EC-6 with CCB III Page 29
9 Technical Data
9.1 EC-6
Input voltage AC 100 to 240 V
Line frequency 50 to 60 Hz
Max.* nominal current (at AC 100 V) 2 A
U1 (motor) U2 (sensors)
Output voltage DC 24 V DC 23 V
Max.* nominal output current 2.5 A 50 mA
Peak output current (for max. 200 ms) 14 A
IP protection class IP 54, CAT 2, UL50 type 3R
Dimensions 245 mm x 162 mm x 66 mm
Total weight including 2 MLD sensors Approx. 2 kg
* depend on the size of the system and project specific loads.
9.2 CCB
Input voltage AC 100 to 240 V
Line frequency 50 to 60 Hz
Nominal current 1 A
Output voltage DC 21 V
Output current DC 1.4 A
IP protection class IP 54, CAT 2, UL50 type 3R
Dimensions 250 mm x 180 mm x 160 mm
Total weight including wind monitor Approx. 4 kg
9.3 Wind monitor
Input voltage L-N AC 100 to 240 V
Line frequency 50 to 60 Hz
Nominal current: 1.1 A
IP protection class NEMA 4X, IP 54
Dimensions 250 mm x 180 mm x 110 mm
Weight Approx. 3,000 g
9.4 Climatic conditions
According to DIN EN 50178:1998-04
Installation AMSL (above mean sea level) Max. 2,000 m
Permissible ambient temperature -20 °C to +50 °C
Barometric pressure range 70 kPa to 106 kPa
Air humidity range 5% to 95%
Expanded air humidity range 0% to 100% (for wind monitor Advanced)