01/10/2021 ASSEMBLY INSTRUCTIONS MLD Control EC-6 with CCB III Page 19
4.2 Anemometer Installation with Old Wind Monitor
The anemometer having 3 wires ( Red, Yellow & Black ) should be connected to old wind monitor as shown
below:
Anemometer
Old Wind Monitor
Red Wire
Terminal +
White Wire
Terminal 35
Black Wire
Terminal -
4.3 Assembly
4.3.1 On building
ATTENTION!
The anemometer must be installed perpendicular and minimum at the height of the upper edge of
the module surface in a location where it is exposed to wind.
The anemometer should not be installed in the wind shadow of objects.
4.3.2 On the DEGER system
The only way a DEGER wind monitor (anemometer) can be attached directly to a DEGER system is by
installing the optionally available pendulum kit of DEGER. The pendulum kit can be used with all DEGER
wind monitors.
ATTENTION!
The cable for the anemometer must be routed in such a way that it will not be damaged by
the nodal bar. If the cable becomes damaged, it will pose a danger by preventing the module
surface from moving into the SAFE position (table position) when the wind speed is too high
(except for when the broken wire detector is connected).
1. The pre-assembled pendulum kit has to be fastened to the DEGER system on the left side of the module
surface, when viewed from the rear, using the aluminum profile F-SET-X. The distance between outer edge
of module and nodal bar must be 200 mm.