Figure 6 Installing a power cooling module
2. For an AC power cooling module:
a.
Plug the power cord into the power cooling module.
b. Secure the power cord with the retention bail at the connector. The bail prevents the
power cord from pulling out of the connector.
Figure 7 Plugging in and securing the power cord
3. For a DC power cooling module, push the power cord plug into the connector until it snaps
in place. The clips on the plug prevents the power cord from pulling out of the connector.
Verify the power supplies
Procedure
1.
Enter the enclosure show powersupply command to find the status of all the power
modules.
# enclosure show powersupply
This command may take up to a minute to complete. Please wait...
Enclosure Description Status
--------- ------------------- -----
4 Power module A OK
4 Power module B OK
--------- -------------------- ------
Removing and replacing FRUs