Number Severity Description/Recommended actions
Recommended actions:
• Take appropriate action based on the indicated problem.
Info. The scheduler experienced a problem with the indicated task.
Recommended actions:
• No action is required.
363 Error When the Management Controller (MC) is restarted, rmware versions that are currently installed are
compared against those in the bundle that was most recently installed. When rmware is updated, it is
important that all components are successfully updated or the system may not work correctly. Components
checked include the CPLD, Expander Controller (EC), Storage Controller (SC), and MC.
Recommended actions:
• Reinstall the rmware bundle.
Info. When the Management Controller (MC) is restarted, rmware versions that are currently installed are
compared against those in the bundle that was most recently installed. If the versions match, this event is
logged as Informational severity. Components checked include the CPLD, Expander Controller (EC), Storage
Controller (SC), and MC.
Recommended actions:
• No action is required.
364 Info. The broadcast bus is running as generation 1.
Recommended actions:
• No action is required.
365 Error An uncorrectable ECC error occurred in Storage Controller CPU memory more than once, indicating a
probable hardware fault.
Recommended actions:
• Replace the controller module that logged this event.
Warning An uncorrectable ECC error occurred in Storage Controller CPU memory.
This event is logged with Warning severity to provide information that may be useful to technical support, but
no action is required now. It will be logged with Error severity if it is necessary to replace the controller module.
Recommended actions:
• No action is required.
400 Info. The indicated log has lled to a level at which it needs to be transferred to a log-collection system.
Recommended actions:
• No action is required.
401 Warning The indicated log has lled to a level at which diagnostic data will be lost if not transferred to a log-collection
system.
Recommended actions:
• Transfer the log le to the log-collection system.
402 Error The indicated log has wrapped and has started to overwrite its oldest diagnostic data.
112 Events and event messages