Number Severity Description/Recommended actions
This is normally used to import into the system an FDE disk that was locked by another system.
Recommended actions:
• Ensure that the imported disk(s) are integrated into the system.
512 Info. The system was set to the FDE secured state by a user.
Full Disk Encryption is now enabled. Disks removed from this system will not be readable unless they are
imported into another system.
Recommended actions:
• No action is required.
513 Info. The system was set to the FDE repurposed state by a user.
All disks have been repurposed and set to their initial factory states. FDE is no longer enabled on the system.
Recommended actions:
• No action is required.
514 Info. The FDE lock key and import key were cleared by a user.
I/O operations may continue as long as the system is not restarted.
Recommended actions:
• If the system is restarted and access to data is intended, the lock key must be reinstated.
515 Info. An FDE disk was repurposed by a user.
The disk was reset to its original factory state.
Recommended actions:
• No action is required.
516 Error An FDE disk has been placed in the unavailable state.
The related event message 518, which indicates that a disk operation failed, may provide additional
information.
Recommended actions:
• See the recommended action specied in the event message.
517 Info. A disk that was formerly in the FDE unavailable state is no longer unavailable.
The disk has returned to normal operations.
Recommended actions:
• No action is required.
518 Error An FDE disk operation has failed.
This event provides detail about the operation that failed.
Recommended actions:
• The disk may need to be removed, imported, repurposed, or replaced.
521 Error An error occurred while accessing the midplane SEEPROM to store or fetch Full Disk Encryption keys.
122 Events and event messages