Number Severity Description/Recommended actions
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure
status page in the supported diagnostic list.
Recommended actions:
Upgrade the controller module to the latest supported bundle version.
528 Error Expander Controller rmware detected that the partner Expander Controller (EC) rmware is incompatible
with the enclosure.
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure
status page in the supported diagnostic list.
Recommended actions:
Upgrade the partner controller module to the latest supported bundle version.
529 Error The local Expander Controller (EC) is incompatible with the enclosure.
As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure
status page in the supported diagnostic list.
Recommended actions:
Replace the controller module with one that is compatible with the enclosure.
530 Error The local Expander Controller (EC) rmware detected a level of incompatibility with the partner Expander
Controller (EC). This incompatibility could be due to unsupported hardware or rmware.
As a preventative measure, the local Expander Controller (EC) is holding the partner Expander Controller (EC)
in a reset loop.
Recommended actions:
Remove the partner controller module from the enclosure. Boot the partner controller module in single-
controller mode in a separate enclosure (without the controller module that reported this event). Load the
latest compatible bundle version. If the version fails to load, replace the partner controller module.
531 Error The indicated controller module was unable to recover from a stall. The system will need to be manually
recovered.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.
Warning The indicated controller module detected a stall. The system will perform corrective actions.
Recommended actions:
No action is required.
533 Error This event provides details about the result of the MC test of the indicated component.
If the test succeeded, the message says the component is present and operational. If the test failed, the
message says the component is unavailable.
Recommended actions:
If the event indicates the test failed, replace the controller module that logged this event.
Info. This event provides details about the result of the MC test of the indicated component.
Recommended actions:
124 Events and event messages