Loading...
NOTE: Ensure that the PHM is held parallel to the system board to prevent damaging the components.
2 Push the blue retention clips inward to allow the heat sink to drop into place.
3 Using the Torx #T30 screwdriver, tighten the screws on the heat sink in the order below:
a Partially tighten the rst screw (approximately 3 turns).
b Tighten the second screw completely.
c Return to the rst screw and tighten it completely.
If the PHM slips o the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a Loosen both the heat sink screws completely.
b Lower the PHM on to the blue retention clips, following the procedure described in step 2.
c Secure the PHM to the system board, following the replacement instructions listed in this step above. 4.
Figure 64. Installing the processor and heat sink module
Next steps
1 Install the air shroud.
2 Follow the procedure listed in After working inside your system.
112