EasyManua.ls Logo

Dell EMC PowerEdge R540 - Installing Cooling Fan

Dell EMC PowerEdge R540
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 34. Removing cooling fan
Next steps
1 Installing cooling fan.
2 Installing the internal PERC riser
3 Installing the air shroud
4 Follow the procedure listed in After working inside your system.
Installing cooling fan
The procedure for installing standard and high performance fans are identical.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Removing the air shroud
4 Removing the internal PERC riser
5 Remove the power cable.
6 Move the cables out of the way to access the cooling fan cable connector on the system board.
Steps
1 Holding the release tab blue touch point, place the cooling fan into the cooling fan cage.
2 Route the cooling fan cable and connect it to the connector on the system board.
82
Installing and removing system components

Table of Contents