Loading...
Figure 42. Installing PERC card into internal PERC riser
Next steps
1 Installing the internal PERC riser
2 Installing the air shroud
3 Follow the procedure listed in After working inside your system.
Intrusion switch
Removing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Removing the air shroud
4 Removing the internal PERC riser
Steps
1 Disconnect the intrusion switch cable connected to the system board.
NOTE
: Ensure that you note the routing of the cables as you remove them from the system board.
2 Slide the intrusion switch out of the intrusion switch slot.
Installing and removing system components