Thermal restriction matrix
Table 33. Thermal restriction matrix for R540
Storage conguration Front 8 drive 12 drive 12 drive
Rear NA NA 2 drive
Fan type Standard fan Standard fan High
performance fan
CPU heat sink type 1.5U heat sink 1.5U heat sink 1U heat sink
Processor
number
TDP (W) Core count Ambient = 35°C Ambient = 35°C Ambient = 30°C Ambient = 30°C
Intel Xenon Gold
6138
125 20
Yes Yes Yes Yes
Intel Xenon Gold
6130
125 16
Yes Yes Yes Yes
Intel Xenon Gold
6126
125 12
Yes Yes Yes Yes
Intel Xenon Gold
6128
115 6
Yes No Yes Yes
Intel Xenon Gold
5122
105 4
Yes No Yes Yes
Intel Xenon Gold
5115
85 10
Yes Yes Yes Yes
Intel Xenon Silver
4116
85 12
Yes Yes Yes Yes
Intel Xenon Silver
4114
85 10
Yes Yes Yes Yes
Intel Xenon Silver
4110
85 8
Yes Yes Yes Yes
Intel Xenon
Bronze 3106
85 8
Yes Yes Yes Yes
Intel Xenon
Bronze 3104
85 6
Yes Yes Yes Yes
Intel Xenon Silver
4112
85 4
Yes Yes Yes Yes
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If
the levels of particulates or gaseous pollution exceed the specied limitations and result in equipment damage or failure, you may need to
rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
40
Technical specications