Figure 55. Installing a memory module
Next steps
1 Install the air shroud
2 Follow the procedure listed in After working inside your system.
3 To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System BIOS >
Memory Settings. In the Memory Settings screen, the System Memory Size must reect the updated capacity of the installed
memory.
4 If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is rmly
seated in the memory module socket.
5 Run the system memory test in system diagnostics.
Cooling fans
Removing the internal cooling fan
Prerequisites
CAUTION
: Never operate your system with the internal cooling fan removed. The system can overheat and result in shutdown of
the system and loss of data.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the air shroud.
Steps
1 Disconnect the internal cooling fan power cable from the system board.
2 Holding the internal cooling fan, press the release tab, and slide the cooling fan out in the direction of the arrow marked on the fan.
CAUTION
: Do not remove or install the internal cooling fan by holding the fan blades.
108 Installing and removing system components