Table 21. Maximum shock specications
Maximum shock Specications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 6 G for up to 11 ms.
Storage 6 consecutively executed shock pulses in the positive and negative x, y, and
z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 22. Maximum altitude specications
Maximum altitude Specications
Operating
3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 23. Operating temperature derating specications
Operating temperature derating Specications
Up to 35°C (95°F) Maximum temperature reduces by 1°C/300 m (1°F/547 ft) above 950 m
(3,117 ft).
35 °C–40°C (95 °F–104°F) Maximum temperature reduces by 1°C/175 m (1°F/319 ft) above 950 m
(3,117 ft).
40 °C–45°C (104 °F–113°F) Maximum temperature reduces by 1°C/125 m (1°F/228 ft) above 950 m
(3,117 ft).
Standard operating temperature
Table 24. Standard operating temperature
specications
Standard operating temperature Specications
Continuous operation (for altitude less than 950 m or 3117
ft)
10°C–35°C (50°F–95°F) with no direct sunlight on the equipment.
Expanded operating temperature
Table 25. Expanded operating temperature
specications
Expanded operating
temperature
Specications
Continuous operation 5°C–40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C–35°C), the system can operate
continuously in temperatures as low as 5°C and as high as 40°C.
34 Technical specications