Figure 56. Removing the internal cooling fan
Next steps
1 Follow the procedure listed in After working inside your system.
2 Install the internal cooling fan.
Installing the internal cooling fan
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the air shroud.
4 If installed, remove the front bezel.
Steps
1 Hold the cooling fan by the sides with the cable end facing the bottom of the system.
2 Align the four tabs on the internal cooling fan with the four slots on the system wall.
3 Press and slide the internal cooling fan into the slots until the release tab locks into place.
4 Connect the internal cooling fan power cable to the connector on the system board.
Figure 57. Installing the internal cooling fan
Next steps
1 Install the air shroud.