Processors and heat sinks
Removing a processor and heat sink module
Prerequisites
WARNING
: The heat sink may be hot to touch for some time after the system is powered down. Allow the heat sink to cool
before removing it.
1
Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the air shroud.
Steps
1 Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a Loosen the rst screw three turns.
b Loosen the second screw completely.
c Return to the rst screw and loosen it completely.
2 Pushing both blue retention clips simultaneously, lift the processor and heat sink module (PHM) processor and heat sink module
Installing and removing system components
121