3. After confirming that the cluster has shut down, disconnect the power cables from both nodes in one of the base enclosures
in the cluster, if required. Wait a few seconds and confirm that all remaining LEDs have turned off.
4. If your cluster has more than one appliance, repeat steps 3 and 4 to disconnect power from the remaining appliances in the
cluster.
Powering on procedures for PowerStore cluster
This section includes the following procedures:
Power on a PowerStore T model cluster on page 120
Power on a PowerStore T model cluster
About this task
Use the following procedure to power on a PowerStore T model cluster:
Steps
1. If nodes were removed, reseat the nodes into the relevant base enclosure chassis.
2. If applicable, for each appliance in the cluster, ensure that expansion enclosures are also reseated into the cabinet.
3. For each appliance, reconnect the power cables to node A first, and then node B.
The Node Power LED on each node turns on when the power cable is connected.