Dell EMC PowerStore 500T - Return a Faulted Part; Replace an I;O Module; Before You Begin; Identify a Faulted I;O Module from Powerstore Manager

Dell EMC PowerStore 500T
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. The status of the replacement SFP module should read Healthy. If the status is still Faulted, wait a few minutes
and refresh PowerStore Manager. If the fault was indicated by one of the following error messages, verify that the error
message is cleared:
SFP speed mismatched
SFP unsupported
SFP asymmetric
If the status does not change or the error message is not cleared, ensure that the SFP module is correctly seated, or contact
your service provider.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1. Package the faulted part in the shipping box that contained the replacement part.
2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3. For more information about returning customer-replaceable parts:
a. Open PowerStore Manager.
b. Click Settings on the upper right of the screen.
c. Click General Support.
d. Under Drives, Power Supplies, and Other Parts, click Return Part.
e. If your screen does not show the Return Part link, contact your service provider for instructions.
Replace an I/O module
Take the following actions to remove the faulted I/O module and install the replacement I/O module into the system.
Before you begin
CAUTION:
Before starting this procedure, use the PowerStore Manager Hardware view and Alerts view to verify
that the appliance and peer node are healthy with no outstanding alerts. If multiple nodes need to be removed
while performing this procedure, repeat this verification for each affected node before proceeding to remove
the next node. If necessary, contact your service provider before starting the replacement procedure.
Identify a faulted I/O module from PowerStore Manager
Before you replace an I/O module, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted I/O module.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that includes the I/O module that you need to replace.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Expand the node that includes the I/O module, and then select the relevant IoModule.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.
Base enclosure service procedures
59