Table 5. Embedded module LEDs (continued)
LED Location State Description
Node power Green Node is on (main power).
Green blinking Node is initializing a serial over LAN
session.
Off Node is off.
Node fault Amber Fault has occurred.
Blue Node in Degraded Mode.
Amber or blue
blinking
System is booting.
Blue and amber
alternating (green
for 3 seconds)
System not initialized. A management IP
address has not been assigned.
Blue and amber
alternating at one
second intervals
Node in Service Mode.
Off No fault has occurred, normal operation.
4-port card port link Green Link up with high speed
Amber Link up with degraded speed
Off Link down
Ethernet port activity Amber blinking Port activity.
Off No port activity.
Ethernet port link Green Link established.
Off No link established.
SAS port/activity link Blue Not used
Off Not used
2-port card port link
Embedded module power Amber Embedded module has faulted.
Off No fault has occurred, normal operation.
Power down the node
Power down the node as described in Power control procedures.
Remove the node
This procedure describes how to remove a node from the chassis. There are two nodes. The top node is considered to be
upside-down and mirrors the bottom node. The procedure for removing the top node and the bottom node is the same.
Prerequisites
If the I/O modules and network cables are not already labeled, label them clearly for reconnecting later.
50
Base enclosure service procedures