Base enclosure I/O module LEDs
Use the fault LEDs to identify the faulted part.
NOTE: The ports look different depending on whether they are for copper or optical connections. The image below shows
ports for copper cables.
Figure 62. Base enclosure I/O module LEDs
Table 6. Base enclosure I/O module LEDs
LED Location State Description
Port link Green or blue Link up
Off Link down
Power/Fault Green Power on
Amber Fault
Power down the node
Power down the node as described in Power control procedures.
Remove an I/O module
Steps
1. Pull the trigger mechanism on the I/O module handle to release it.
CAUTION: Do not pull the node from the base enclosure.
Figure 63. Releasing the I/O module
2. Gently pull the I/O module from the slot.
60
Base enclosure service procedures